Transmitted spectrophotometer LTS-A13 with table top design is used to measure the transmittance, absorbency, concentration as well as reflectance of the material. Equipped with SCS system for best measurement repeatability & accurate measurement of surface color of material. The double grating & double optical path splitting system & ETC (every test calibration technology) produces 0.01% resolution, color balance intensity across visible spectrum & highly accurate measurements.
| Sensor | Dual light path sensor array |
| Weight | 7 kg |
| Interface | USB |
| Color space | CIE-L*a*b, L*C*h, L*u*v, XYZ, Yxy, Transmittance, Hunterlab, Munsell Mi, CMYK |
| Data storage | Mass storage (on PC) |
| Light source | A, C, D50, D65, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12, DLF, TL183, TL184, NBF, U30, CWF |
| Measurement time | 2 s |
| Wavelength range | 400-700 nm |
| Dimension (L*W*H) | 475 × 340 × 150 mm |
| Observation Angle | 2°/10° |
| Measuring aperture | 25.5*10 mm (cuvette support) |
| Half spectral width | 5 nm |
| Illumination system | d/0 (Diffused lighting, 0° observation viewing), SCS optical engine (light splitting and integration system), ETC (every time calibration technology), SCI (specular reflection included)/ SCE (specular reflection excluded) simultaneous measurement |
| Wavelength interval | 10 nm |
| Data being displayed | Sample's color values,color difference values/graph,pass/fail results,color error tendency,color value simulation, color difference values, display measurement area,history data color simulation,manual input standard sample, generate measurement report |
| Light source longevity | 5 years, 1.5 million tests |
| Work temperature range | 0-45°C, relative humidity 80% or below (at 35°C), no condensation |
| Illumination light source | CLED |
| Measurement time interval | 0.5 s |
| Size of integrated sphere | 40 mm, alvan diffused reflection surface coating |
| Storage temperature range | 25℃ to 55℃ relative humidity 80% or below(at 35°C ),no condensation |
| Reflectivity range & resolution | 0 to 200%, 0.01% |
Transmittance spectrophotometer is used in the measurement of range of liquids and solvents like resins, solvents, oils etc. to be used in food, chemical, textile, life science industries.
Atomic Absorption Spectrophotometer LAAS-A11
✓ Wavelength range : 190 - 900 nm
✓ Spectral Bandwidth : 0.2 nm, 0.4 nm, 0.7 nm, 1.4 nm, 2.4 nm, 5.0 nm
Flame Atomic Absorption Spectrophotometer LAAS-A12
✓ Wavelength range : 190 nm ~ 900 nm
✓ Spectral bandwidth : 0.1 nm, 0.2 nm, 1.0 nm, 2.0 nm
Atomic Absorption Spectrophotometer LAAS-A13
✓ Working spectral range : 190 to 900 nm
✓ Spectral Bandwith : 0.1, 0.2, 0.4, 1.0 and 2.0 nm
Atomic Absorption Spectrophotometer LAAS-A20
✓ Wavelength range : 180 - 900 nm
✓ Spectral Bandwidth : 0, 0.2, 0.4, 1.0, 2.0nm (Automatic setting)
Atomic Absorption Spectrophotometer LAAS-A21
✓ Wavelength range : 180 – 900 nm
✓ Spectral Bandwidth : 0 nm, 0.2 nm, 0.4 nm, 1.0 nm, 2.0 nm(5 steps with automatic changeover)