info@labodam.com
+44 20 3371 7320 Mon - Sat: 9:00 AM - 6:00 PM
Home All Products Spectrometer XRD Diffractometer LD-LXRD-A10
XRD Diffractometer LD-LXRD-A10

XRD Diffractometer LD-LXRD-A10

SKU: LD-LXRD-A10

XRD DiffractometerLD-LXRD-A10contains tube current up to 5 to 80 mA with a dimension 1 × 10 mm/ 0.4 × 14 mm/ 2 × 12 mm and are designed for quality diffraction data, combined with ease of use and flexibility to quickly switch to different applications, This multipurpose diffractometers are all equipped with X-ray tuble of glass tube, ceramic tube, ripple ceramic tube with many different X-ray source materials (Cu, Fe, Co, Cr and Mo) and is coupled with an auto-switching dual wavelength optic. It have Low maintenance, high performance system and designed with Horizontal Goniometer structure and proportional/Scintillation counters detector.

  • ✓ Diffractometer is equipped with X-ray tuble of glass tube, ceramic tube, and ripple ceramic tube with many different X-ray source materials (Cu, Fe, Co, Cr and Mo)
  • ✓ Coupled with an auto-switching dual wavelength optic
  • ✓ Horizontal Goniometer structure
  • ✓ Proportional/Scintillation counters detector
  • ✓ For testing unknown samples it has phase identification and phase analysis for known mixed samples
  • ✓ Crystal structure varies with temperature (high temperature vice versa) factor and chemical information tested by X-ray diffraction test device
  • ✓ Equipped with programmable operation, integrated structure design with easy operation and well-designed outlook
  • ✓ High throughput with high accuracy diffraction angle measurement
  • ✓ Scanning range and Scanning speed are well design in equipment
Also available in:
X-ray Tuble : Glass tube, Ceramic tube, Ripple Ceramic tube: Cu, Fe, Co, Cr, Mo etc., Power 2 kW
WeightAbout 25 kg
DetectorProportional/Scintillation counters
Dimension1100 × 850 × 1750 mm
Stability≤ 0.01 %
Focus Size1 × 10 mm/ 0.4 × 14 mm/ 2 × 12 mm
Rated Power3 kW
X-ray TubleGlass tube, Ceramic tube, Ripple Ceramic tube: Cu, Fe, Co, Cr, Mo etc., Power 2 kW
Tube Current5 to 80 mA
Tube Voltage10 to 60 kV
Scanning ModeØ to 2 Ø linkage, Ø, 2 Ø single action; continuous/stepping scanning
Scanning Range0 to 164
Scanning Speed0.0012º to 70 º min
Counting FashionDifferential Coefficient / integral, PHA automatically, Dead time regulate
Scattered Rays Dose≤ 1 µ Sv/h (without X-ray protective device)
Goniometer StructureHorizontal (Ø to 2 Ø )
Radius of Diffraction185 mm
Minimal Stepping Angle1 / 1000 º
Energy Resolution Ratio≤ 25 % (PC), ≤ 50 % (SC)
Maximum Resolving Speed100 º / min
Angle Repeatable Accuracy1 / 1000 º
Stability of System measure≤ 0.01 %
Instrument Integrative Stability≤ 0.5 %
Maximum Counting rate of Linearity5 × 105 CPS (with the compensate function of dropout counting)

Best suited for the research and industrial product analysis with perfect combination of conventional analysis crucial measurement product and for academics and researchers in different application areas.

Similar Products